Breathing Air Filters

breathing air filters


For the most efficient use of Ultra Pure Oil free Compressed Air

BREATHING AIR QUALITY
AIR FILTER
ULTRA PURE AIR QUALITY
FILTERS AND FILTER CARTRIDGES
Breathing air purifiers without CO or CO2 removal

How to Install

  • Install filters downstream of aftercoolers and air receivers at the lowest installation temperature and as close to the point application as possible. This ensures in wet systems as much water and oil vapour has condensed out as possible which can be removed by the coalescing filters.
  • Installing close to the application reduces the risk of pipe scale.
  • Filters should not be installed downstream of quick opening valves and should be protected from possible reverse flow or other shock conditions.
  • Install a combination of main line filtration near the compressor installation before entry to the ring main and install terminal filtration at the critical points. Remember especially in existing installations the contamination already in the pipe system downstream of the filters will take a long time to disappear and probably never will completely. E. Purge all lines leading to the filters before installation. F. Install filters in a vertical position keeping sufficient place below the filters for element change
General Uses of Zeroil Hunter Filters
GENERAL PURPOSE PROTECTION
Air Quality to ISO 8573.1 : Class 2.-3. Bulk Liquid and Solid Removal
OIL-LUBRICATED ZH-OR
OIL-FREE COMPRESSORS
zeroil hunter filter
General Ring Main Protection
Particle Removal Only (Dry Systems)
Pre-filteration to High Efficiency Filters(Grade ZH-AA)
Pre-filteration for Refrigerant Air Dryers
'OIL-FREE' AIR
Air Quality to ISO 8573.1 : Class 1..-2.Alternative to 'Oil Free' Compressors
OIL-LUBRICATED ZH-OR
OIL-FREE COMPRESSORS
zeroil hunter filter
High Quality Compressed Air Instrumentation
Pre-filteration for Adsorption Type Dryers
Pre-filteration to Air Sterilisation Filters
EXTREMELY LOW DEWPOINT SYSTEM
Air Quality to ISO 8573.1 : Class 1.1.1 and 1.2.1 Pressure Dewpoint -70 0 C to 40 0 C
OIL-LUBRICATED ZH-OR
OIL-FREE COMPRESSORS
ZH-AR/ZH-AAR
FILTERS GRADES
zeroil hunter filter
REDUCED DEWPOINT SYSTEM
Air Quality to ISO 8573.1 : Class 1.4.1 and Pressure Dewpoint greater than +2 0 C

OIL-LUBRICATED ZH-OR
ZH-OR OIL-FREE COMPRESSORS
zeroil hunter filter

TERMINAL FILTERATION
Air Quality to ISO 8573.1 : Class 1.4.1 and 1.2.1 Pressure Dewpoint greater than +2 0 C
zeroil hunter filter
CRITICAL APPLICATIONS
Air Quality to ISO 8573.1 : Class 1.-.1 Highest Quality - Clean, Oil Free and Odour Free and Odour Free Compressed Air
OIL-LUBRICATED
ZH-OR OIL-FREE COMPRESSOR
zeroil hunter filter
Foodstuffs Production Packaging
Beverage Production / Packaging / Transport
Pharmaceutical Production
5 previous

Daytona Engineers
          Plot No.57, Behind Honda Showroom,Near Police Station, Western Express Highway, 

      Mira - 401104,Dist. Thane Tel :+ 91-022 2845 56 81, 2845 61 08, Telefax:+ 91-022 2845 5681

Cell :-  09323799899,  09322676880,  09323294671

 Email : neumatic@vsnl.com , daytona@vsnl.net

Branch
Neumatic Shoppe
Nasik Phata Signal, Mumbai-Pune Rd, Kasarwadi, Pune-411 034. Maharashtra (India)

Tel :+ 91-020 27110942, Fax :+ 91-020 27110943. Cell :- 09822092701.

Email : neumatic@vsnl.com, daytona@vsnl.net